John-Paul Hosom's extension of the Tinseth formula, Microbrew.it's "mibu" setting. Tinseth counts only the boil; mIBU also integrates the isomerisation that continues after flameout while the wort cools, which is what makes whirlpool and hop-stand additions register. IBU = (U_boil + U_post) × AA × W × 1000 ÷ V U_boil: Tinseth's utilization for the boil time (see Tinseth IBU) U_post = ∫ dU/dt × U_rel(T(t)) dt over the cooling period dU/dt = 1.65 × 0.000125^(G − 1) × 0.04 × e^(−0.04 × t) ÷ 4.15 T(t) = 53.7 × e^(−b × t_cool) + 319.55 (kelvin) b = 0.0002925 × A_eff ÷ V + 0.00538 U_rel(T) = min(1, 2.39 × 10¹¹ × e^(−9773 ÷ T)) A_eff: effective open area of the kettle, cm², the geometric mean of the wort surface and the lid opening V: wort volume, L; t_cool: minutes since flameout AA, W, G as for Tinseth T(t) is a fitted cooling curve for an uncovered kettle; U_rel is the isomerisation rate relative to boiling, an Arrhenius term that halves by about 88 °C. Microbrew.it integrates by the midpoint rule in steps of at most 0.01 minutes. With no cooling period mIBU equals Tinseth exactly. For 21 L of wort in an uncovered kettle about 30 cm across, a 20-minute stand that stays on T(t) adds about 165 % to a 5-minute addition, 75 % to a 10-minute one, 45 % to a 15-minute one and 4 % to a 60-minute one, compared with chilling at flameout. The cooling period is read off the whirlpool's stands, in order. The wort starts on T(t) and stays on it through every stand that finishes no colder than T(t) would be at the stand's end. The first stand that finishes colder is forced cooling: from it on, each stand runs in a straight line from where the wort was to the temperature it finishes at, and a hold stays at its own temperature. A zero-minute stand adds nothing, but a forced one moves the wort to its temperature. The integral ends with the last stand. A hop added in the whirlpool has no boil time and starts at the minute it goes in; the other IBU formulas give it no bitterness. Hosom's calculator treats a hop stand differently: its hold option chills exponentially at 0.6075 × e^(−0.0704 × V) per minute, adds the chill time to the stand, and integrates through the final chill.