Terrill refractometer correction

Terrill refractometer correctionKB

A refractometer measures how strongly a sample bends light. In wort that follows the sugar, but alcohol bends light too, so once fermentation has started a Brix reading on its own overstates the gravity. Sean Terrill's 2011 cubic estimates the gravity of fermenting or finished beer from two readings, the one taken before pitching and the one taken now: FG = 1.0000 − 0.0044993 × OB + 0.011774 × FB + 0.00027581 × OB² − 0.0012717 × FB² − 0.0000072800 × OB³ + 0.000063293 × FB³ OB: original refractometer reading in °Bx ÷ WCF FB: current refractometer reading in °Bx ÷ WCF WCF: wort correction factor, 1.04 FG: gravity now, specific gravity The wort correction factor allows for wort not being pure sucrose, which is what refractometers are calibrated on. When the original gravity was measured with a hydrometer, OB is that gravity in °Plato, which is what a refractometer reading divided by the WCF would have given. A beer that read 12 °Bx at pitch and 6 °Bx at the end is at about 1.011, where reading 6 °Bx as unfermented wort would say 1.023. Terrill fitted the cubic to finished beers between 73 and 91 % apparent attenuation, so it is least reliable early in fermentation and on beers that finish sweet, while the plain Brix-to-gravity conversion is valid only before fermentation starts. Just after pitching it can be well off: 10 °Bx before and after reads 1.028 rather than the wort's 1.038.